{"product_id":"parker-5500-series-self-sealing-brass-quick-disconnect-coupling-pair-1-4-odf-copper-750-psi-r32-r290-r454b-compatible-low-loss-refrigerant-coupling","title":"Parker 5500 Series — Self-Sealing Brass Quick-Disconnect Coupling Pair | 1\/4\" ODF Copper | 750 psi | R32 \/ R290 \/ R454B Compatible | Low-Loss Refrigerant Coupling","description":"\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Parker 5500 Series is a self-sealing brass quick-disconnect coupling designed for field-serviceable and modular refrigeration systems. This listing provides a matched male\/female pair — a 5502 male coupling half and a 5505 female coupling half — each with a 1\/4\" ODF (outside diameter flared) copper sweat connection on a 3\/8\" (-06) coupling body. When threaded together, the pair opens a sealed refrigerant path; when separated, independent spring-loaded poppet valves in each half snap shut, containing system charge on both sides and admitting less than 0.15 cc of air per connection cycle.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe design is purpose-built for split and modular HVAC\/R configurations where evaporator or other circuit components need to be swapped without recovering system charge. That makes this coupling pair a natural fit for the Kippkitts 1 kW air-air heat pump platform, where flexible hoses terminated with these quick-disconnects allow different evaporator modules to be connected and disconnected from the outdoor unit without releasing refrigerant or requiring re-evacuation. The all-brass body and refrigeration-grade copper sweat connections are chemically compatible with R32, R290, R454B, R600a, R410A, R22, R134a, R404A, R407C, and R507 — covering the full range of current and forward-looking low-GWP refrigerants relevant to residential and light-commercial heat pump design.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe metal-to-metal final seal formed when the union nut is fully tightened gives this coupling a connected leak rate under 0.1 oz of R22-equivalent per year — negligible for precision heat pump circuits where charge integrity is critical to COP. The thread-together design allows connection and disconnection under system pressure, meaning the circuit does not need to be depressurized before swapping an evaporator module in the field.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eParker Hannifin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5500 Self-Sealing Brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMale half part number\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5502-04B-06 (with plastic cap)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFemale half part number\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5505-04B-06 (with plastic plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSold as\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMatched male + female pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCoupling body size\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-06 (3\/8\" \/ 9.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCopper connection size\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-04 (1\/4\" ODF \/ 6.4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConnection type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCopper sweat (braze)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCoupling body material\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBrass bar, ASTM-B16, Alloy C3600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConnection material\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigeration-grade copper, ASTM-B75, Alloy C12200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInternal assembly material\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eASTM-B16 Alloy C360 \u0026amp; zinc trivalent chromate plated steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePoppet seal (male)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNeoprene™ bonded poppet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSleeve seal (female)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNeoprene™ bonded sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating pressure (connected)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVacuum to 750 psi (52 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating pressure (male, disconnected)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVacuum to 750 psi (52 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating pressure (female, disconnected)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVacuum to 600 psi (41 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMinimum burst pressure (connected)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2,700 psi (186 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMinimum burst pressure (male, disconnected)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2,700 psi (186 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMinimum burst pressure (female, disconnected)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,800 psi (124 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e–40°F to +250°F (–40°C to +121°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax air inclusion per connection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.15 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax fluid loss per disconnection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.10 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConnected external leak rate\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u0026lt; 0.1 oz R22-equivalent per year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDisconnected leak rate (without cap\/plug)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u0026lt; 0.50 oz R22-equivalent per year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDisconnected leak rate (with cap\/plug)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eN\/A — -06 body size does not include metal cap\/plug option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOverall length, disconnected (female half)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3.14 in (79.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOverall length, disconnected (male half)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2.58 in (65.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCoupled overall length\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e4.77 in (121.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eUnion nut thread (female hex nut)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eM20-1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCoupling body hex (female)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.75 in (19.1 mm) across flats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eUnion nut hex (female)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.94 in (23.9 mm) across flats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRecommended connection torque (male to female)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e18–20 ft·lbs (24.4–27.1 N·m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant compatibility\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR22, R32, R134a, R290, R404A, R407C, R410A, R454B, R507, R600a (and polyolester, PAG, mineral, and alkylbenzene oils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVibration resistance\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eUL 109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRoHS compliant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eAgency approvals\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\n\u003cp\u003eUL Listed, File No. SA7511\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eConnection \/ Integration\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eCoupling Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe 5500 Series uses a thread-together union nut design with three sequential sealing stages:\u003c\/p\u003e\n\u003col class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-decimal flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eDisconnected\u003c\/strong\u003e — Spring-loaded poppets in both halves are closed. The male poppet seats against surface \"A\" of the male body; the female sleeve seats against the stem valve head at surface \"B\". An O-ring on the female sleeve provides secondary sealing in this state.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003ePartially connected\u003c\/strong\u003e — As the union nut engages, the male body's sealing surface \"C\" contacts the female sleeve before either poppet opens. Both valves remain sealed during thread engagement, so refrigerant cannot escape even while the coupling is being assembled under pressure.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eFully connected\u003c\/strong\u003e — Continued tightening draws the poppets open and simultaneously drives a metal sealing ring (located at the front face of the male coupling) into the brass seat of the female half, forming the primary metal-to-metal leak seal. Refrigerant flow path is now open.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eDisconnecting under pressure\u003c\/strong\u003e is permitted. Reverse the above sequence; both poppets re-seat before any refrigerant path opens to atmosphere.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTorque values\u003c\/strong\u003e for the -06 body size:\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eJoint\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eft·lbs\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eN·m\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMale half to female half (union nut)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e18–20\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e24.4–27.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eUse torque values above, or the marker\/1\/4-turn-past-contact method described in the assembly instructions. Do not rotate the female coupling body during tightening — only the union nut should turn.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eIntegration Notes\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eApplication context.\u003c\/strong\u003e In the Kippkitts 1 kW heat pump platform, these couplings are intended to terminate the flexible refrigerant hoses that connect the outdoor unit to swappable evaporator modules. The male half (5502) brazed to the system side, the female half (5505) on the evaporator module, is the recommended convention — this leaves the lower disconnected burst pressure on the female side (the removable component) and the higher-rated male half on the permanently plumbed system side.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eTubing size transition.\u003c\/strong\u003e The Danfoss GBC16S ball valve (009L8053) paired with these couplings in the Kippkitts BOM has a 5\/8\" ODF connection. A short copper reducing stub (5\/8\" ODF → 1\/4\" ODF, or an intermediate step through 3\/8\" ODF) must be brazed between the valve and the coupling. This stub can be fabricated from refrigeration-grade ACR copper tubing. Parker also offers a range of braze adapters under the 202208-xx-4B part number family if a machined adapter is preferred.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBrazing discipline.\u003c\/strong\u003e Use paste flux sparingly on the tube only — not on the coupling body. Protect the coupling with a flowing water bath or chill blocks during brazing to prevent internal seal damage. Quench the assembly below 400°F before releasing from the water bath. See Parker Catalog OEM-1 assembly instructions for full brazing procedure.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eLubrication.\u003c\/strong\u003e Before each connection, wipe the rubber poppet and union nut threads with refrigeration-grade oil compatible with the system charge. For R290 and R600a (hydrocarbon) systems, use a polyolester oil. For R32\/R454B systems, polyolester is also recommended. Do not use mineral oil with HFO or HFC refrigerants.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eRefrigerant oil compatibility.\u003c\/strong\u003e Parker confirms compatibility with R22 + mineral\/alkylbenzene\/POE\/PAG oils, and R134a\/R404A\/R407C\/R410A\/R507 + polyolester oil. For R32, R290, R454B, and R600a, verify oil compatibility with your system oil supplier; Parker recommends contacting them directly for refrigerant oils not listed in the original datasheet.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003e-06 body size cap\/plug limitation.\u003c\/strong\u003e The -06 coupling body size does not have a metal protective cap\/plug option — only plastic (included with B-suffix parts). Store and ship with plastic caps\/plugs installed and reinstall them when the evaporator module is disconnected from the system. Inspect the Neoprene poppet and sleeve seals for damage before reconnecting after extended storage.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eConnection under pressure.\u003c\/strong\u003e The coupling can be connected and disconnected under operating system pressure (up to 750 psi on the male side). Ensure coupling faces are parallel and free of lateral load before starting the union nut by hand. If the nut does not start freely by hand, do not force it — realign the hose to remove side-load before threading.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMTBF\/L10 life.\u003c\/strong\u003e Cycle life and MTBF data are not published in Parker Catalog OEM-1 for this series. Contact Parker Hannifin A\/C \u0026amp; Refrigeration Aftermarket (Washington, MO) for MTTF data if long-life or high-cycle-count qualification is required for your application.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eParallel use.\u003c\/strong\u003e Each coupling half is an independent sealed unit. Multiple pairs can be used in parallel circuits (e.g., liquid line and suction line) without interaction. Route the suction-line coupling where it is accessible for the higher torque values that may result from larger body sizes in future kit revisions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eIncluded Accessories\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e1× Parker 5502-04B-06 male coupling half (with plastic protective cap)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e1× Parker 5505-04B-06 female coupling half (with plastic protective plug)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cem\u003eBraze adapters, reducing stubs, and flexible hose assemblies are sold separately.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"kippkitts","offers":[{"title":"Default Title","offer_id":47242205724843,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0355\/1037\/files\/IMG_0053.jpg?v=1781717278","url":"https:\/\/www.kippkitts.com\/products\/parker-5500-series-self-sealing-brass-quick-disconnect-coupling-pair-1-4-odf-copper-750-psi-r32-r290-r454b-compatible-low-loss-refrigerant-coupling","provider":"kippkitts","version":"1.0","type":"link"}